IP67 vs IP65 LED Strip: The Real Difference
IP65 and IP67 LED strips differ in water protection. Learn what the ratings mean, how coating affects heat, and which suits outdoor signage.
GMH Lighting · Published August 24, 2026 · Updated October 5, 2026 · 4 min read
IP65 and IP67 are ingress protection ratings: IP65 means protection against low-pressure water jets, while IP67 means protection against temporary immersion in up to 1 m of water for 30 minutes. For LED strips, IP65 usually means a silicone or PU coating and IP67 a fuller encapsulation. Outdoor signage exposed to rain typically uses IP65; locations where water pools need IP67.
Key points
- IP65 resists water jets from any direction; IP67 survives immersion up to 1 m for 30 minutes.
- IP65 strips are usually surface-coated; IP67 strips are fully encapsulated in silicone.
- Encapsulation traps heat, so designers often derate coated strips by roughly 10–20%.
- Vertical outdoor sign faces typically use IP65; horizontal or washdown areas need IP67.
What the IP code means
IP stands for ingress protection, and the two digits describe protection against solids and liquids. The first digit, 6, is the same in both ratings and means the strip is dust-tight. The difference is entirely in the second digit: 5 or 7.
| Rating | Solid protection | Water protection | Practical meaning |
|---|---|---|---|
| IP65 | Dust-tight | Low-pressure jets from any direction | Rain and splash resistant |
| IP67 | Dust-tight | Temporary immersion up to 1 m / 30 min | Can survive brief submersion |
These definitions come from the general IP code convention (IEC 60529), which is an industry standard, not a company-specific figure.
Construction differences
The rating is achieved by how the strip is built. An IP65 strip is usually a bare flexible PCB with a thin silicone or polyurethane coating over the diodes. An IP67 strip is more fully encapsulated, often with a silicone sleeve or a solid extrusion around the entire board.
| Feature | IP65 strip | IP67 strip |
|---|---|---|
| Protection method | Thin surface coating | Full silicone encapsulation |
| Flexibility | High, bends easily | Stiffer, larger bend radius |
| Heat dissipation | Better | Reduced, traps heat |
| Typical use | Vertical signs, interiors | Wet locations, washdown areas |
Heat is the hidden trade-off
The more thoroughly a strip is sealed, the harder it is for heat to escape. An IP67 strip running at the same current as an uncoated strip will operate hotter because the silicone acts as an insulator. Hotter LEDs age faster and lose output sooner.
For that reason, designers often derate coated strips by roughly 10–20% — running them at a lower current than they would a bare strip. This is a typical industry practice, not a fixed rule. If in doubt, measure the strip temperature at its hottest point after an hour of operation.
Choosing for outdoor signage
Use this simple decision path:
- Vertical face, normal rain: IP65 is usually adequate.
- Horizontal face, standing water: IP67 is the safer choice.
- Pressure-washed or marine location: IP67, plus sealed connectors.
- Interior, dry location: an uncoated strip is fine and runs coolest.
Remember that water enters through joints first. Even an IP67 strip will fail at a cut end or connector that was not resealed. Specify IP-rated connectors and end caps as part of the same order.
The LED strips product page lists the available coated formats for different environments.
Common mistakes
- Assuming a higher number is always better. IP67 costs more, runs hotter and is stiffer.
- Ignoring the power supply and connectors. The system is only as sealed as its weakest part.
- Cutting an IP67 strip and leaving the end open. Reseal every cut.
- Running a coated strip at full current in a hot enclosure. Derate and ventilate.
- Reusing a cut-off section. Once an end has been cut and resealed poorly, it is the first place water will enter.
- Assuming the rating lasts forever. Silicone ages and seals harden; inspect outdoor runs every 12 months.
A simple way to extend service life is to avoid mounting the strip where water can sit against it for hours. Even an IP67 product is designed for temporary, not continuous, immersion. Where a sign is regularly washed, choose a location that drains freely and let the strip dry between cycles.
Installation details that break the rating
The IP rating applies to the strip as supplied, not to the finished sign. Four details decide whether an installed run actually keeps that protection.
- Cable entry. Bring cables in through a sealed gland from below where possible, so water drains away rather than into the fitting.
- Cut ends. Every cut on an IP67 strip must be resealed with silicone or an end cap. An unsealed cut drops protection to roughly IP20 at that point.
- Connectors. Use connectors with a matching or higher rating. A standard IP20 connector on an IP67 strip creates a weak point.
- Drainage. Horizontal surfaces should be tilted slightly so water cannot pool on the strip.
Heat management matters too. A fully encapsulated IP67 strip in a sealed aluminium channel can reach temperatures that shorten LED life. Provide some ventilation and avoid running the strip at its maximum rated current; roughly 10–20% derating is a common design choice for coated products.
Finally, remember that the power supply and controller also need protection. An IP67 run fed from an unsealed supply in a wet location will fail at the supply, not at the LEDs. The system should be specified as a whole, with every component rated for the same environment.
Scope and limits
This page does not cover the detailed chemistry of silicone and polyurethane coatings, nor the full IEC 60529 test procedures. It does not address chemical resistance to solvents, fuels or salt spray, which require separate specifications. It also excludes waterproof LED modules and neon flex products, which are different formats with their own rating systems.
Related reading
- LED neon flex vs LED strip: which for signage
- How to choose LED modules for channel letters and lightboxes
- Color temperature and CRI for advertising signage